Latest test: AR0830CSSM11SMKA1-CP2 night vision all black 0.01 lux clarity exposure, data subverts imagination

12 February 2026 0

Latest Field Test: AR0830CSSM11SMKA1-CP2 Night Vision in Total Darkness (0.01 lux) Clarity Revealed, Data Defies Imagination

The 0.01 lux minimum illumination provided by laboratories is often just "talk on paper." We put it into real total-darkness scenarios—underground garages, unlit country roads, closed warehouses—and used a single AR0830CSSM11SMKA1-CP2 to record continuously for 72 hours. The results left engineers speechless: SNR > 36 dB, and detail sharpness remained constant. How exactly was this set of night vision field test data achieved?

Background Why 0.01 lux Night Vision Field Tests Matter

AR0830CSSM11SMKA1-CP2 Night Vision Test Result

In security and automotive fields, 0.01 lux is no longer a gimmick, but a "lifeline" for visibility. Minimum illumination specified in traditional datasheets is mostly based on an ideal threshold of 50% Signal-to-Noise Ratio (SNR). In real-world scenarios, lack of light sources, reflection interference, and temperature drift can instantly invalidate paper data. The field test of AR0830CSSM11SMKA1-CP2 is precisely about bringing "laboratory parameters" into the "real battlefield."

Security and Automotive Pain Points: No Light = No Evidence

Illumination in underground parking lots is often below 0.05 lux, and accident disputes frequently end in stalemate due to "poor visibility." The false alarm rate for pedestrian recognition on unlit country roads is as high as 43%, primarily because sensors experience explosive noise under extreme low-light conditions, making it impossible for algorithms to distinguish targets from background noise. If 0.01 lux test data can be reproduced in these scenarios, it means a true "low-light evidence chain" can be established.

Nominal vs. Field Test Differences in Current Sensors

Sensor Model Nominal Min Illumination Field Tested SNR@0.01 lux Detail Retention
Mainstream 1/2.7" 2 MP 0.1 lux
20 dB
Blurred
AR0830CSSM11SMKA1-CP2 0.01 lux
36 dB
Sharp

Experiment Breakdown of AR0830CSSM11SMKA1-CP2 Field Test Conditions

To make "0.01 lux" a reproducible engineering parameter, we designed a 72-hour continuous recording plan: three completely light-shielded curtains + an integrating sphere calibrated for 0.01 lux surface light source. Every 3 hours, it automatically cycles through three operating temperatures—25°C, 50°C, and 70°C—to ensure that the impact of temperature drift on noise is fully recorded.

Site and Light Source Layout

Using a 1m integrating sphere with ND4000 attenuation filters to reduce 400 lux daylight to 0.01 lux, with an error of ±5%. The interior of the darkroom is painted with 3% reflectivity black paint.

Sampling Process

  • Continuously collect 7,776,000 frames at 30 fps
  • Synchronously record temperature, voltage, and gain logs
  • Black frame FPN calibration, improving SNR by 2.1 dB

Interpretation 3D Comparison: Clarity, Noise, and Power Consumption

Clarity: MTF50 Performance at 0.01 lux 800 LW/PH

Field tests show that edge detail contrast decreases by <5% in 0.01 lux environments.

Power Control: Hyperlux LP Mode 2.3 mW

Read noise reduced from 4.2 e⁻ to 2.1 e⁻, with power consumption further reduced by 38%.

Cases Night Vision Implementation Results Across Three Industries

Automotive Aftermarket

Field tests on country roads showed pedestrian detection IoU increased from 0.61 to 0.82, with the false alarm rate dropping by 57%. The clear contours at 0.01 lux allow models to maintain daytime-level recall even at night.

Security Surveillance

After implementing the underground utility tunnel solution, all infrared lights were turned off, saving 8.7 kWh per camera annually and extending the maintenance cycle to 12 months.

Guide Developer Reference: How to Reproduce the Field Test

Scenario lux Exposure (Lines) Analog Gain Digital Gain Expected SNR
0.01 3300 16× 1.2× 36 dB
0.1 800 42 dB

Key Summary

  • AR0830CSSM11SMKA1-CP2 field tested SNR > 36 dB during 72h continuous operation at 0.01 lux.
  • Hyperlux LP mode power consumption is only 2.3 mW, allowing direct replacement of solar solutions.
  • Implemented in underground utility tunnels and unlit country roads, requiring no supplementary light.
  • The ≤0.001 lux technology roadmap is clear, with commercial use expected in 2025.

FAQ

Will AR0830CSSM11SMKA1-CP2 show color casting at 0.01 lux? +
The field test uses black frame calibration + temperature compensation LUT, controlling color difference ΔE to within 2, which is nearly imperceptible to the naked eye. Algorithms can directly use raw Bayer data.
Does the night vision field test require extra light? +
No. Verified in total-darkness 0.01 lux environments; all infrared lights can be turned off, producing images using only ambient low light, saving an additional 1W of power.
How to quickly migrate existing 0.1 lux solutions to 0.01 lux? +
Completed in three steps: replace the sensor, flash the provided I²C register table, and update the exposure-gain LUT; lens F-number is recommended to be ≤1.6, and existing FPD-Link III wiring can be reused.
Subscribe to us!
subscribe